Specifications:
Input voltages | CSA | 480/600 V, 3-PH, 50/60 Hz |
---|---|---|
CE | 400 V, 3-PH, 50/60 Hz | |
CCC | 380 V, 3-PH, 50/60 Hz | |
Input current @ 21.9 kW | 300/400/480/600 V, 38/36/31/24 A | |
Output current | 30–125 A | |
Rated output voltage | 175 VDC | |
Duty cycle @ 40° C (104° F) | 100% @ 125 A | |
Open circuit voltage (OCV) |
| |
Dimensions with handles | 592 mm D; 274 mm W; 508 mm H (23.3″ D; 10.8″ W; 20.0″ H) | |
Weight with 7.6 m (25′) torch |
| |
Gas supply | Clean, dry, oil-free air or nitrogen | |
Recommended gas inlet flow rate/pressure | Cutting: 260 l/min (550 scfh) @ 5.9 bar (85 psi) Gouging: 212 l/min (450 scfh) @ 4.1 bar (60 psi) | |
Input power cable length | 3 m (10′) * | |
Power supply type | Inverter – IGBT | |
Engine drive requirement | 40 kW for full 125 A output | |
Certifications | CSA-certified for use in the Americas and Asia, except China. CE, C-Tick, CU/GOST, Ukr, and Serbian – for use in Europe, Australia, Belarus, Kazakhstan, Russia, Serbia, Ukraine, and other countries where accepted. CCC for use in China. | |
Warranty | Power supplies have a 3-year warranty and torches a 1-year warranty. |
*No power cord on some CCC models.
Engine-driven generator operation:
Engine drive rating | System output current | Performance (arc stretch) |
---|---|---|
40 kW | 125 A | Full |
30 kW | 125 A | Limited |
30 kW | 100 A | Full |
25 kW | 100 A | Limited |
22.5 kW | 75 A | Full |
20 kW | 75 A | Limited |
20 kW | 60 A | Full |
15 kW | 60 A | Limited |
12 kW | 40 A | Full |
10 kW | 40 A | Limited |
10 kW | 30 A | Full |
8 kW | 30 A | Limited |
Capacity:
Capacity | Thickness | Cut speed |
---|---|---|
Cutting | ||
Recommended | 38 mm (1-1/2″) | 457 mm/min (18 ipm) |
44 mm (1-3/4″) | 250 mm/min (10 ipm) | |
Severance (hand cutting) | 57 mm (2-1/4″) | 125 mm/min (5 ipm) |
Pierce * | 25 mm (1″) |
* Pierce rating for handheld use or with automatic torch height control
Capacity | Metal removal rate | Groove profile |
---|---|---|
Gouging | ||
Typical gouge | 12,52 kg/hr (27.6 lbs./hr) | 4,3 mm–7,9 mm D x 6,1 mm–9,9 mm W (0.17–0.31″ D x 0.24–0.39″ W) |
Specifications
- Brand : Hypertherm
- Category : Plasma Cutting
Customers also purchased:



Call for price
Compare


Call for price
Compare

Call for price
Compare



selection not available, try a different combination
selection not available, try a different combination
Call for price
Compare

Fetching product details
Description
Specifications:
Input voltages | CSA | 480/600 V, 3-PH, 50/60 Hz |
---|---|---|
CE | 400 V, 3-PH, 50/60 Hz | |
CCC | 380 V, 3-PH, 50/60 Hz | |
Input current @ 21.9 kW | 300/400/480/600 V, 38/36/31/24 A | |
Output current | 30–125 A | |
Rated output voltage | 175 VDC | |
Duty cycle @ 40° C (104° F) | 100% @ 125 A | |
Open circuit voltage (OCV) |
| |
Dimensions with handles | 592 mm D; 274 mm W; 508 mm H (23.3″ D; 10.8″ W; 20.0″ H) | |
Weight with 7.6 m (25′) torch |
| |
Gas supply | Clean, dry, oil-free air or nitrogen | |
Recommended gas inlet flow rate/pressure | Cutting: 260 l/min (550 scfh) @ 5.9 bar (85 psi) Gouging: 212 l/min (450 scfh) @ 4.1 bar (60 psi) | |
Input power cable length | 3 m (10′) * | |
Power supply type | Inverter – IGBT | |
Engine drive requirement | 40 kW for full 125 A output | |
Certifications | CSA-certified for use in the Americas and Asia, except China. CE, C-Tick, CU/GOST, Ukr, and Serbian – for use in Europe, Australia, Belarus, Kazakhstan, Russia, Serbia, Ukraine, and other countries where accepted. CCC for use in China. | |
Warranty | Power supplies have a 3-year warranty and torches a 1-year warranty. |
*No power cord on some CCC models.
Engine-driven generator operation:
Engine drive rating | System output current | Performance (arc stretch) |
---|---|---|
40 kW | 125 A | Full |
30 kW | 125 A | Limited |
30 kW | 100 A | Full |
25 kW | 100 A | Limited |
22.5 kW | 75 A | Full |
20 kW | 75 A | Limited |
20 kW | 60 A | Full |
15 kW | 60 A | Limited |
12 kW | 40 A | Full |
10 kW | 40 A | Limited |
10 kW | 30 A | Full |
8 kW | 30 A | Limited |
Capacity:
Capacity | Thickness | Cut speed |
---|---|---|
Cutting | ||
Recommended | 38 mm (1-1/2″) | 457 mm/min (18 ipm) |
44 mm (1-3/4″) | 250 mm/min (10 ipm) | |
Severance (hand cutting) | 57 mm (2-1/4″) | 125 mm/min (5 ipm) |
Pierce * | 25 mm (1″) |
* Pierce rating for handheld use or with automatic torch height control
Capacity | Metal removal rate | Groove profile |
---|---|---|
Gouging | ||
Typical gouge | 12,52 kg/hr (27.6 lbs./hr) | 4,3 mm–7,9 mm D x 6,1 mm–9,9 mm W (0.17–0.31″ D x 0.24–0.39″ W) |
Specifications
- Brand : Hypertherm
- Category : Plasma Cutting
Customers also purchased:



Call for price
Compare


Call for price
Compare

Call for price
Compare



selection not available, try a different combination
selection not available, try a different combination
Call for price
Compare
Product Added to Basket
Don't forget to add your bins!
Based on your request, you need Calculating... to transport and store your dry ice.

Your total product weight is Calculating...
The bin capacity is Calculating...
Our dry ice is made fresh to order, please have your orders in by 2pm the day before your scheduled delivery day. Off day and late orders may incur additional delivery fees.
Dry Ice Cancellation Policy
Dry ice orders cancelled within 24 hours of their scheduled delivery date will be charged the full order amount. Orders cancelled before 24 hours of their scheduled delivery date will not be charged to the customer.